4Q Drives
l Complete 4 quadrant operation
l Near perfect sine wave line current
l No need to use dynamic braking resistor
l Keeping the DC bus voltage constant
l The feedback energy of the motor can be given to the power grid
l Not like traditional converter to pollute the power grid
1140V
(160KW~600KW)
Rating Power(KW) |
132 |
160 |
185 |
220 |
250 |
280 |
315 |
400 |
Rating Output Current(A) |
155 |
179 |
207 |
250 |
280 |
313 |
352 |
448 |
Rating Input Current(A) |
137 |
161 |
186 |
225 |
252 |
282 |
317 |
402 |
AC Input Voltage(V) |
1140Vac +/- 20% |
|||||||
Input Frequency |
48 ~ 62 Hz |
|||||||
AC Output Voltage |
0 to input voltage |
|||||||
AC Output Frequency |
0 to 200 Hz |
|||||||
Overload |
150% , continuous 1 minute |
|||||||
Control System |
Sensorless flux Vector , Sine coded PWM |
|||||||
Frequency Resolution |
0.10% |
|||||||
Frequency Linearity |
0.2% of maximum frequency |
|||||||
Communications |
BACNET, Profibus, Modbus, lonWorks, Metasys via RS-485 (option) |
|||||||
Accel & Decel Time |
Independent Accel & Decel adjustment with S-curve |
|||||||
Analogue Input/Output |
0~5V , 0~10V ; 0~20mA , 4~20mA |
|||||||
Digital Input |
5 Digital input with programmable control functionality |
|||||||
Relay Output |
2 relays type NO / NC with programmable functionality |
|||||||
Local Control |
Comprehensive local control include Start (FWD/REV) , Stop , Reset , and Set Speed |
|||||||
Display Screen |
16 character*2 line alphanumeric , Backlight and auto contrast . |
|||||||
Run Variables |
Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature , I2t used process variable scale |
|||||||
Protection |
Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature |
|||||||
Operating Temperature |
0 ~ 40oC |
660V
(132KW~600KW)
Rating Power(KW) | 160 | 185 | 220 | 250 | 280 | 315 | 400 | 600 | |
Rating Output Current(A) | 155 | 179 | 207 | 250 | 280 | 313 | 352 | 448 | 671 |
Rating Input Current(A) | 137 | 161 | 186 | 225 | 252 | 282 | 317 | 402 | 604 |
AC Input Voltage(V) | 660Vac +/- 20% | ||||||||
Input Frequency | 48 ~ 62 Hz | ||||||||
AC Output Voltage | 0 to input voltage | ||||||||
AC Output Frequency | 0 to 200 Hz | ||||||||
Overload | 200% , continuous 1 minute | ||||||||
Control System | Sensorless flux Vector , Sine coded PWM | ||||||||
Frequency Resolution | 0.10% | ||||||||
Frequency Linearity | 0.2% of maximum frequency | ||||||||
Communications | BACNET, Profibus, Modbus, lonWorks, Metasys via RS-485 (option) | ||||||||
Accel & Decel Time | Independent Accel & Decel adjustment with S-curve | ||||||||
Analogue Input/Output | 0~5V , 0~10V ; 0~20mA , 4~20mA | ||||||||
Digital Input | 5 Digital input with programmable control functionality | ||||||||
Relay Output | 2 relays type NO / NC with programmable functionality | ||||||||
Local Control | Comprehensive local control include Start (FWD/REV) , Stop , Reset , and Set Speed | ||||||||
Display Screen | 16 character*2 line alphanumeric , Backlight and auto contrast . | ||||||||
Run Variables | Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature , I2t used process variable scale | ||||||||
Protection | Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature | ||||||||
Operating Temperature | 0 ~ 40oC |
(15KW~450KW)
Rating Power(KW) | 15 | 20 | 30 | 45 | 55 | 75 | 90 | 132 | 185 | 220 | 250 | 315 | 400 | 450 |
Rating Output Current(A) | 30 | 40 | 57 | 88 | 109 | 140 | 170 | 260 | 360 | 430 | 490 | 610 | 780 | 875 |
Rating Input Current(A) | 27 | 36 | 54 | 81 | 99 | 135 | 162 | 237 | 333 | 395 | 449 | 566 | 719 | 808 |
AC Input Voltage(V) | 380Vac +/- 20% | |||||||||||||
Input Frequency | 48 ~ 62 Hz | |||||||||||||
AC Output Voltage | 0 to input voltage | |||||||||||||
AC Output Frequency | 0 to 200 Hz | |||||||||||||
Overload | 125% | |||||||||||||
Control System | Sensorless flux Vector , Sine coded PWM | |||||||||||||
Frequency Resolution | 0.10% | |||||||||||||
Frequency Linearity | 0.2% of maximum frequency | |||||||||||||
Communications | BACNET, Profibus, Modbus, lonWorks, Metasys via RS-485 (option) | |||||||||||||
Accel & Decel Time | Independent Accel & Decel adjustment with S-curve | |||||||||||||
Analogue Input/Output | 0~5V , 0~10V ; 0~20mA , 4~20mA | |||||||||||||
Digital Input | 5 Digital input with programmable control functionality | |||||||||||||
Relay Output | 2 relays type NO / NC with programmable functionality | |||||||||||||
Local Control | Comprehensive local control include Start (FWD/REV) , Stop , Reset , and Set Speed | |||||||||||||
Display Screen | 16 character*2 line alphanumeric , Backlight and auto contrast . | |||||||||||||
Run Variables | Output frequency(Hz) , Motor Speed(RPM) , % Load , Output current(A) , Power(KW) , Output Voltage(V) , Temperature , I2t used process variable scale | |||||||||||||
Protection | Current limit , Over voltage , Under voltage , Short circuit , Earth fault , Phase monitoring , Motor electronic thermal overload , Over temperature | |||||||||||||
Operating Temperature | 0 ~ 40oC |